Quantcast
Channel: Intel Communities : Popular Discussions - Servers
Viewing all 3319 articles
Browse latest View live

S2600CP very loud fan

$
0
0

I have Intel Server Board S2600CP in Intel Server Chassis P4000S with 5 fan coolers. Server two year worked correctly. But, one weak ago, 5 fan coolers started working too fast and too load. Installed one processor - Xeon E5-2603, and her temperature about 30 C.

I upgrade BIOS on last firmware: BIOS - 02.06.0005, ME - 02.01.07.328, BMC - 01.27.9958, FRUSDR - 1.11. During upgrade i set Chassis serial number, Chassis part number, System serial number and System part number correctly.

In BIOS settings set parameters: Set Throttling Mode - [Auto], Altitude -[300m or less], Set Fan Profile - [Acoustic]. For tests i set various parameters in BIOS, but 5 fan coolers worked very fast and very load all time.

Ask me please, how to diagnostic and correctly configure my server.

 

Thanks.


S3420GP and RAM

$
0
0

Hello,

I have a server mothebord S3420GP with 6 memory slots.

Now, I have 2 slots filled with these: 2x KINGSTON 4GB 1333MHz DDR3 ECC CL9 DIMM with Thermal Sensor.

 

Is possible to use another 4 these RAMs? So I would have 24 GB RAM with 6 x 4 GB. Is this combination possible?

 

Or is possible to use 4 x KINGSTON 8GB DDR3 1333MHz CL9 ECC Dual Rank BOX.

So total memory size will be 32 GB RAM.

 

Thanks for any answers.

 

raw ipmi command to retrieve NIC 1 MAC address on S2600GZ

$
0
0

Hi there,

 

what is the right approach to retrieve the NIC 1 MAC address (for OS usage) via IPMI?

 

NOTE: I am assuming the system is powered off and that a DHCP server assigned an IP address to the BMC LAN channel 1.

 

The S2600GZ technical product specification section 6.10.3.2.3 highlights the convention used to assign MAC address so conceptually one could calculate it from the BMC LAN channel 1 MAC address (by subtracting 4) but that seems brittle so I am looking for the (raw) IPMI command to provide that info directly!?

 

Other vendors implemented vendor-specific IPMI commands but I can't seem to find the doc that would cover an S2600GZ board..

 

Thanks & cheerio, Harry.

S2600CP very loud fan

$
0
0

I have Intel Server Board S2600CP in Intel Server Chassis P4000S with 5 fan coolers. Server two year worked correctly. But, one weak ago, 5 fan coolers started working too fast and too load. Installed one processor - Xeon E5-2603, and her temperature about 30 C.

I upgrade BIOS on last firmware: BIOS - 02.06.0005, ME - 02.01.07.328, BMC - 01.27.9958, FRUSDR - 1.11. During upgrade i set Chassis serial number, Chassis part number, System serial number and System part number correctly.

In BIOS settings set parameters: Set Throttling Mode - [Auto], Altitude -[300m or less], Set Fan Profile - [Acoustic]. For tests i set various parameters in BIOS, but 5 fan coolers worked very fast and very load all time.

Ask me please, how to diagnostic and correctly configure my server.

 

Thanks.

first start problem

$
0
0

I had created a operating software from bootable usb device but I am getting this error: "Initializing and Establishing Link"  . I am using a SR1550AL server and I thing I should disable network from bios but couldnt find disable option any help about it?

How do I update the BIOS on a very old S2600CP motherboard?

$
0
0

Hi,

 

I've just been given an ancient, refurbished S2600CP2J motherboard complete with CPUs and RAM and would like to get it fully working again.

 

The obvious first step is to update the BIOS but the oldest EFI update package available (01.02.003) states that I need to have at least version 01.01.1002 before starting or "the update process may render the system not operatable!"

 

According to the BIOS screen, my system is currently SE5C600.86B.99.99.x034, build date 08/23/2011.

 

As I have no wish to kill the system before I get started, is there any way of upgrading it to 01.01.1002 as a minimum?

 

Thanks.

Intel® Modular Server Chassis MFSYS25 not enough power supply units.

$
0
0

Hello!
I have Intel MFSYS25 in this configuration:
6 modules of computer modules MFS5520VI.
4 modules DPS-1000DB A 1050W Power Supply, all power supply modules are connected to the power network.

At the moment, only two blades of six work.
When trying to start one or more, the chassis writes this:

error.JPG

What happened?And why can not I run more than two blades?

S3420GP and RAM

$
0
0

Hello,

I have a server mothebord S3420GP with 6 memory slots.

Now, I have 2 slots filled with these: 2x KINGSTON 4GB 1333MHz DDR3 ECC CL9 DIMM with Thermal Sensor.

 

Is possible to use another 4 these RAMs? So I would have 24 GB RAM with 6 x 4 GB. Is this combination possible?

 

Or is possible to use 4 x KINGSTON 8GB DDR3 1333MHz CL9 ECC Dual Rank BOX.

So total memory size will be 32 GB RAM.

 

Thanks for any answers.

 


Controller ID: 0 PD Predictive failure Question

$
0
0

My question is how the heck do I determine which drive is about to fail, without having to pull the system offline and run SMART checks on each drive.

Here's the event:

"

Controller ID:  0   PD Predictive failure: 

    Int.Ports 4-7:2:0

Event ID:96

"

 

OS is Server 2008 R2

 

 

Thanks in advance for the assistance.

raw ipmi command to retrieve NIC 1 MAC address on S2600GZ

$
0
0

Hi there,

 

what is the right approach to retrieve the NIC 1 MAC address (for OS usage) via IPMI?

 

NOTE: I am assuming the system is powered off and that a DHCP server assigned an IP address to the BMC LAN channel 1.

 

The S2600GZ technical product specification section 6.10.3.2.3 highlights the convention used to assign MAC address so conceptually one could calculate it from the BMC LAN channel 1 MAC address (by subtracting 4) but that seems brittle so I am looking for the (raw) IPMI command to provide that info directly!?

 

Other vendors implemented vendor-specific IPMI commands but I can't seem to find the doc that would cover an S2600GZ board..

 

Thanks & cheerio, Harry.

X5460 vs E5450

$
0
0

Hi Folks,

On paper I can see the differenc between the X5460 and E5450 (namely 120W vs 80W and 3.16Ghz vs 3.00Ghz).

But can someone help with information like the following:

 

Are there any major differences between the chips in their spec and expected compute power?

Does anyone have benchmarks to compare the two?

 

Thanks,

Gerald

STOP 0x00000124 BSoD on S1200SPLR

$
0
0

STOP 0x00000124 BSoD occured in the following environment and at the following timing.

 

The environment
-S1200SPLR (FW:03.01.0021)
-Windows 2016 standard (clean installed)
-Pentium G4560
-SanMax SMD4-E16G28H-21P-D DDR4-2133 U-DIMM ECC 8GBx2
-AVAGO MegaRAID 9265-8i (PCIe x8)
-Intel Expander RES2SV240 (PCIe x4)
-Broadcom BCM957810A1006G 10GbE (PCIe x8)
-Samsung SSD 840 EVO (SATA)

 

When BSoD occurs
-Run Windows Update
-Install Chipset Driver

 

I tried the following, but I did not improve it.

 

-Remove all PCIe cards
-Run Memtest86 >> no error
-clean install OS
-Replace the keyboard and mouse

 

Thank you for your assistance.

MFSYS25 Activate Features

$
0
0

Hello,

I have Blade Servers on MFSYS25, and I need at least activate Advanced Management Pack (MFSADVMGMT) for SysLog feature.

In a good case, I need the same for Shared LUN (MFSLUNKEY).

Our distributor said that he can't help us in this matter.

What should I do in this case?

Thank you.

how can i save configure switch on Intel Modular Server

$
0
0

Hi every one!

 

Please help me this case, I use a Intel Modular Server,

 

When i configure Switch on the Modular server, i could not save configure.

 

after switch restart, the switch does not save my configre and go to factory default

 

How can i save the switch

 

thanks

X5460 vs E5450

$
0
0

Hi Folks,

On paper I can see the differenc between the X5460 and E5450 (namely 120W vs 80W and 3.16Ghz vs 3.00Ghz).

But can someone help with information like the following:

 

Are there any major differences between the chips in their spec and expected compute power?

Does anyone have benchmarks to compare the two?

 

Thanks,

Gerald


How do I update the BIOS on a very old S2600CP motherboard?

$
0
0

Hi,

 

I've just been given an ancient, refurbished S2600CP2J motherboard complete with CPUs and RAM and would like to get it fully working again.

 

The obvious first step is to update the BIOS but the oldest EFI update package available (01.02.003) states that I need to have at least version 01.01.1002 before starting or "the update process may render the system not operatable!"

 

According to the BIOS screen, my system is currently SE5C600.86B.99.99.x034, build date 08/23/2011.

 

As I have no wish to kill the system before I get started, is there any way of upgrading it to 01.01.1002 as a minimum?

 

Thanks.

Ask An Expert - The Server Room

$
0
0

 

Welcome to intel.com/ITopia. Join the discussion, debate and collaborate. This is your opportunity to *ask our experts* what you want to know about Intel’s latest technologies. The floor is yours.
+This discussion is not intended to answer PC support question. If you have a support question go to {document:id=1086}.+

 

S2600WTTR Power failure if USB Disk connected

$
0
0

Hi,

we have several new Servers with the S2600WTTR Mainboard (System BIOS - R01.01.0021 and R01.01.0022).

When we connect a USB 3.0 Disk (WD Elements 2TB), the server beeps and restarts.

 

Beep Code: 1-5-4-2

Associated Sensor: Power fault

Reason for Beep: DC power unexpectedly lost (power good dropout) -Power unit sensors report power unit failure offset...

 

In the BMC Server Health log i have this entries:

 

807/21/2017 16:11:06Pwr Unit StatusPower Unitreports the power unit has suffered a failure - On-board 5V and 3V3 Power failure, - Deasserted
22707/21/2017 16:11:05Pwr Unit StatusPower Unitreports the power unit is powered off or being powered down - Deasserted
22607/21/2017 16:11:00Pwr Unit StatusPower Unitreports the power unit is powered off or being powered down - Asserted

 

Update:

I have this problem on Servers with Vmware installed / also on Systems with Windows - Do i need to check some Bios Settings ?

If the Server stands on BIOS Screen and you connect the USB Disk, also a power fault occure and the server restarts...

 

 

Any ideas ? any help is appreciated! Thanks in advance!

how can i save configure switch on Intel Modular Server

$
0
0

Hi every one!

 

Please help me this case, I use a Intel Modular Server,

 

When i configure Switch on the Modular server, i could not save configure.

 

after switch restart, the switch does not save my configre and go to factory default

 

How can i save the switch

 

thanks

Find old firmware for BMC, server SE7520JR2

$
0
0

Hello, I have a problem. Server board Intel SE7520JR2 with the old version BIOS BMC (version 20). I can not update the firmware to v.52, because new updates are working starting with version 23. Please help me find the firmware BMC ver. 23 for SE7520JR2.

"BMC 0.23 or later must be preinstalled.

If this is not the case, please update the IMM firmware to BMC 0.23 before

updating to this release.

The boot block has been changed with the BMC 0.31 release but it is not

required for this release. The batch file provided with this BMC package

does not update the boot block."

 