S3420GP and RAM

$
0
0

Hello,

I have a server mothebord S3420GP with 6 memory slots.

Now, I have 2 slots filled with these: 2x KINGSTON 4GB 1333MHz DDR3 ECC CL9 DIMM with Thermal Sensor.

 

Is possible to use another 4 these RAMs? So I would have 24 GB RAM with 6 x 4 GB. Is this combination possible?

 

Or is possible to use 4 x KINGSTON 8GB DDR3 1333MHz CL9 ECC Dual Rank BOX.

So total memory size will be 32 GB RAM.

 

Thanks for any answers.

 


first start problem

$
0
0

I had created a operating software from bootable usb device but I am getting this error: "Initializing and Establishing Link"  . I am using a SR1550AL server and I thing I should disable network from bios but couldnt find disable option any help about it?

would E5-2696v2 work on motherboard S2600CP?

$
0
0

Hello,

I went accross 2x E5-2696v2 processors and tried to use them in one of our work stations based on S2600CP or S2600CP4 motherboards. Unfortunately neither of the computers worked with those CPU's. Both of the computers worked fine with 2690 v1 and 2667 v2 though. So my question is: should the two platforms work with E5-2696v2 processors?

 

more specific information about platforms:

 

Chipset: Intel C602 rev. 06

Mainboard Model: S2600CP (0x000001AE - 0x005368B0)

     revision: E99552-510

     serial: QSCP34300402

BIOS: SE5C600.86B.02.02.0002.122320131210 dated at 12/23/2013

where minimum required bios is ver. 02.01.0002 from 09/07/2013

 

the list of compatible processors is: http://www.intel.com/support/motherboards/server/sb/CS-033241.htm

where 2696v2 does no appear.

 

looking forward your help.

 

regards

janusz

P4208CP4MGHC After bios update: Pwr Unit Redund - warning

$
0
0

Hi

 

Hoping for some help to regain the psu reduncy on our P4208CP4MGHC system.

Everything is original and untampered.

 

 

During bios updates last night using OFU I noticed these messages:

 

C:\flashupdt\04>flashupdt -u flashupdt.cfg

        One Boot Flash Update Utility Version 13.1 Build 5
        Copyright (c) 2015 Intel Corporation


SDR Auto-Configuration is not supported on this platform.
Update file Configuration: XXX  S2600CP,2.0

Processing capsule file - .\R02.04.0003.cap

Processing capsule file - .\MEComplete_02.01.07.328.cap
Update file Configuration: Master.cfg, Rev 1.11
S2600CP platform FRU & SDR package version 1.11
Intel(R) Server Board S2600CP platform
Copyright (c) 2010 - 2012 Intel Corporation

Select the function you desire to perform:
1       Update only the SDR repository
2       Update only the FRU repository
3       Update both the FRU and the SDR repository
4       Modify the Product Asset Tag
5       Exit
3

Intel(R) Server Chassis P4000M Redundant Fan SKU is detected

Power supply 1 FRU is invalid.

Power supply 2 FRU is invalid.

8 X 2.5 Hot Swap Backplane 1 is detected.

Probing system for sensors and FRU device hardware...

----------------------------------------------------------------------------------------

 

After succesful completion of the flash and reboot we have this in the event log:

 

EventID:1099   Time Stamp:05/29/2015 00:44:59   SensorName:Pwr Unit Redund       Sensor Type:Power Unit                                Description:reports redundancy has been lost -Asserted

EventID:1100   Time Stamp:05/29/2015 00:44:59   SensorName:Pwr Unit Redund       Sensor Type:Power Unit                                Description:reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation -Asserted

-----------------------------------------------------------

 

In the BMC web console server health I see this:

 

Pwr Unit StatusAll deassertedOK0x0000
Pwr Unit Redundreports redundancy has been lost reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operationWarning0x000A

 

 

-------------------------------------------------------------

 

Is it something in relation to running the updates via OFU and the message stated immediately after starting the update sequece?:

"SDR Auto-Configuration is not supported on this platform"

 

Would rerunning the update package in EFI help the recognition of the psu´s?

 

 

Please if anyone has suggestions on how to work this out chip in.

 

Best Regards Peter

S1200BTLR ipmi-sel output warning:39 | May-30-2015 | 11:15:11 | BB P1 Vcc | Voltage | Lower Non-critical - going low ; Sensor Reading = 0.64 V ; Threshold = 0.64 V

$
0
0

S1200BTLR use Intel(R) Xeon(R) CPU E3-1230 V2 @ 3.30GHz,ipmi-sel output:

[root@T58 ~]# ipmi-sel

ID | Date        | Time     | Name             | Type                     | Event

1  | May-30-2015 | 11:16:30 | System Event Log | Event Logging Disabled   | Log Area Reset/Cleared

2  | May-30-2015 | 11:20:16 | BB P1 Vcc        | Voltage                  | Lower Non-critical - going low ; Sensor Reading = 0.64 V ; Threshold = 0.64 V

3  | May-30-2015 | 11:20:17 | BB P1 Vcc        | Voltage                  | Lower Non-critical - going low ; Sensor Reading = 0.73 V ; Threshold = 0.64 V

4  | May-30-2015 | 11:20:58 | BB P1 Vcc        | Voltage                  | Lower Non-critical - going low ; Sensor Reading = 0.64 V ; Threshold = 0.64 V

5  | May-30-2015 | 11:20:59 | BB P1 Vcc        | Voltage                  | Lower Non-critical - going low ; Sensor Reading = 0.67 V ; Threshold = 0.64 V@

S1200BTL chassis fan running full speed

$
0
0

Hello,

 

I have an S1200BTL motherboard and an P4303xxsfcnna chassis.  I've used Intel Deployment Assistant to update BIOS, BMC, FRU, etc.  The chassis fans are still running at full speed.  The BIOS only has an option to change to altitude, but the fan speed is set to auto and cannot be configured.

Any reason why the fans would be running full speed on both of my systems?

Thanks

Intel adapter teaming issue

$
0
0

So I went to configure adapter teaming and had nothing but problems.  The wizard would start the process, create the Intel Advanced Network Services Virtual Adapter, then hang and not complete any other parts of the process.  I found out that I was using the wrong version of the software for my adapters (which are Pro/1000 MT Dual Port), installed an older version, and all was good to go... except for the 4 Virtual adapters that were created previously by failed attempts of the wizard.  How do I remove these unused virtual adapters from the server?  Simply trying to uninstall them via the device manager doesn't work.  Neither did removing the teaming software, rebooting the server, or simply trying to delete the network connection.

SS4000E failed after power failure.

$
0
0

It says system degraded and all the hard disk lights on the front are red. How can I locate which disk failed. I have a little bit unix experience. I mainly use windows. Since it is degraded, I should be able to recover the files or copy of them if I can bring the system back.

 

 

Dashboard

 

 

Space Usage

 

 

 

Free
0 B

 

Used
0 B

 

Backup
0 B
Total Space0 B

05/31/2015 7:32 pm

 

 

 

 

storage Status

 

Status Messages
4 disks on your storage device have incorrect data on them. Data on the storage device is available but may be lost if another disk fails. Click here to authorize overwriting existing data.

 

Dashboard

 

 

DiskSize
Disk has been replaced with a disk containing data from another system. Disk 1 (ST31500541AS)1.4 TB
Disk has been replaced with a disk containing data from another system. Disk 2 (ST31500541AS)1.4 TB
Disk has been replaced with a disk containing data from another system. Disk 3 (ST31500541AS)1.4 TB
Disk has been replaced with a disk containing data from another system. Disk 4 (ST31500541AS)1.4 TB

Always disabled

None Connected

Click an icon or link to get detailed status information on the device, peripherals, and backups.

A green check means that everything is normal. If a yellow warning, or red error icon appears, your attention is required. Click the link to learn more about the problem or how to

 


first start problem

$
0
0

I had created a operating software from bootable usb device but I am getting this error: "Initializing and Establishing Link"  . I am using a SR1550AL server and I thing I should disable network from bios but couldnt find disable option any help about it?

why i can not get same "netsh int tcp show global" settings with win 8 as 7?

$
0
0

i have a tyan s7025 with two xeon 5520 . i installed win 7 x64 ultimate and win 8 pro x64 .

with win 7 if i use the command : netsh int tcp show global then the result is  :

 

Microsoft Windows [Version 6.1.7601]

Copyright (c) 2009 Microsoft Corporation.  All rights reserved.

 

C:\Windows\system32>netsh int tcp show global

Querying active state...

 

TCP Global Parameters

----------------------------------------------

Receive-Side Scaling State          : enabled

Chimney Offload State               : enabled

NetDMA State                        : enabled

Direct Cache Acess (DCA)            : enabled

Receive Window Auto-Tuning Level    : normal

Add-On Congestion Control Provider  : ctcp

ECN Capability                      : disabled

RFC 1323 Timestamps                 : disabled

 

while with with 8 on the same mainboard with drivers being latest too , i get :

Microsoft Windows [Version 6.2.9200]

(c) 2012 Microsoft Corporation. All rights reserved.

 

C:\Windows\system32>netsh int tcp show global

Querying active state...

 

TCP Global Parameters

----------------------------------------------

Receive-Side Scaling State          : enabled

Chimney Offload State               : disabled

NetDMA State                        : disabled

Direct Cache Access (DCA)           : disabled

Receive Window Auto-Tuning Level    : normal

Add-On Congestion Control Provider  : none

ECN Capability                      : disabled

RFC 1323 Timestamps                 : disabled

Initial RTO                         : 3000

Receive Segment Coalescing State    : disabled

 

despite i added in registry some new keys :

HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters

EnableDCA=1 and EnableTCPA=1

they have no effect even many reboot ... while my settings in win 7 were done without anything in the registry except using tcpoptimizer from speed guide

 

what should i do ?

i also be glad if someone gives a link to a wiki about the registry keys for tcip and the different windows releases, even something [improbable] knowing all the keys of all the windows...

S3420GP and RAM

$
0
0

Hello,

I have a server mothebord S3420GP with 6 memory slots.

Now, I have 2 slots filled with these: 2x KINGSTON 4GB 1333MHz DDR3 ECC CL9 DIMM with Thermal Sensor.

 

Is possible to use another 4 these RAMs? So I would have 24 GB RAM with 6 x 4 GB. Is this combination possible?

 

Or is possible to use 4 x KINGSTON 8GB DDR3 1333MHz CL9 ECC Dual Rank BOX.

So total memory size will be 32 GB RAM.

 

Thanks for any answers.

 

JBOD2312S2SP Power Supply Issue?

$
0
0

I have a JBOD2312S2SP Intel Raid Enclosure (Intel® Storage Systems JBOD Family) at my house and woke up to screaming fan noises.  Warning light was blinking and the console showed this:

 

ID = 206

SEQUENCE NUMBER = 164362

TIME = 29-06-2013 03:13:39

LOCALIZED MESSAGE = Controller ID:  0   Power supply cable removed on enclosure:   1      Power Supply   1

 

Note I only have one power supply so if the cable was removed not sure how it was still running.  Right after that warning received the below messages copied from the logs so the top one is the latest:


ID = 243
SEQUENCE NUMBER = 164371
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164370
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164369
TIME = 29-06-2013 03:13:44
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

ID = 243
SEQUENCE NUMBER = 164368
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164367
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164366
TIME = 29-06-2013 03:13:42
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

ID = 243
SEQUENCE NUMBER = 164365
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       3

ID = 243
SEQUENCE NUMBER = 164364
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       2

ID = 243
SEQUENCE NUMBER = 164363
TIME = 29-06-2013 03:13:40
LOCALIZED MESSAGE = Controller ID:  0   Fan speed changed on enclosure:   1  Fan       1

 

Last message until 6 minutes later I powered up a computer to remove in and shutdown the system.  Pulled the power plug, put it back in, powered everything up, and it's running right now without issue.  Thoughts?

 

Edit:  As a side note, the Intel Raid Web Console shows this drive cage with 2 power supplies.  Always did.  I only have one.  So not sure if that's just how many it can hold or if it's just not intelligent enough to detect the number of drives.

 

Thanks.

 

Steve

SS4000E failed after power failure.

$
0
0

It says system degraded and all the hard disk lights on the front are red. How can I locate which disk failed. I have a little bit unix experience. I mainly use windows. Since it is degraded, I should be able to recover the files or copy of them if I can bring the system back.

 

 

Dashboard

 

 

Space Usage

 

 

 

Free
0 B

 

Used
0 B

 

Backup
0 B
Total Space0 B

05/31/2015 7:32 pm

 

 

 

 

storage Status

 

Status Messages
4 disks on your storage device have incorrect data on them. Data on the storage device is available but may be lost if another disk fails. Click here to authorize overwriting existing data.

 

Dashboard

 

 

DiskSize
Disk has been replaced with a disk containing data from another system. Disk 1 (ST31500541AS)1.4 TB
Disk has been replaced with a disk containing data from another system. Disk 2 (ST31500541AS)1.4 TB
Disk has been replaced with a disk containing data from another system. Disk 3 (ST31500541AS)1.4 TB
Disk has been replaced with a disk containing data from another system. Disk 4 (ST31500541AS)1.4 TB

Always disabled

None Connected

Click an icon or link to get detailed status information on the device, peripherals, and backups.

A green check means that everything is normal. If a yellow warning, or red error icon appears, your attention is required. Click the link to learn more about the problem or how to

 

Is the E3-1246V3 processor compatible with the S1200BTL motherboard

$
0
0

can anyone tell me it the E3-1246 V3 is compatible with the P4304BTLSFCNR server system?

S3420GPRX Bios Recovery image

$
0
0

Hi all my server has been working fine for about 4 Months now and I decided to input the driver disk to run a bios update check. it told me one was available and asked me to select where the source should come from I selected Intel download site and clicked next it hit to a point it was asking me what board I had an I couldn't remember off the top of my head so I told it to exit the process and then it froze so I had to reboot and now it powers on but I don't get any beep codes or bios splash screen. I've tried to flash the CMOS but nothing has change how do I get a Bios recovery image like the manual is referring too


P4208CP4MGHC After bios update: Pwr Unit Redund - warning

$
0
0

Hi

 

Hoping for some help to regain the psu reduncy on our P4208CP4MGHC system.

Everything is original and untampered.

 

 

During bios updates last night using OFU I noticed these messages:

 

C:\flashupdt\04>flashupdt -u flashupdt.cfg

        One Boot Flash Update Utility Version 13.1 Build 5
        Copyright (c) 2015 Intel Corporation


SDR Auto-Configuration is not supported on this platform.
Update file Configuration: XXX  S2600CP,2.0

Processing capsule file - .\R02.04.0003.cap

Processing capsule file - .\MEComplete_02.01.07.328.cap
Update file Configuration: Master.cfg, Rev 1.11
S2600CP platform FRU & SDR package version 1.11
Intel(R) Server Board S2600CP platform
Copyright (c) 2010 - 2012 Intel Corporation

Select the function you desire to perform:
1       Update only the SDR repository
2       Update only the FRU repository
3       Update both the FRU and the SDR repository
4       Modify the Product Asset Tag
5       Exit
3

Intel(R) Server Chassis P4000M Redundant Fan SKU is detected

Power supply 1 FRU is invalid.

Power supply 2 FRU is invalid.

8 X 2.5 Hot Swap Backplane 1 is detected.

Probing system for sensors and FRU device hardware...

----------------------------------------------------------------------------------------

 

After succesful completion of the flash and reboot we have this in the event log:

 

EventID:1099   Time Stamp:05/29/2015 00:44:59   SensorName:Pwr Unit Redund       Sensor Type:Power Unit                                Description:reports redundancy has been lost -Asserted

EventID:1100   Time Stamp:05/29/2015 00:44:59   SensorName:Pwr Unit Redund       Sensor Type:Power Unit                                Description:reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operation -Asserted

-----------------------------------------------------------

 

In the BMC web console server health I see this:

 

Pwr Unit StatusAll deassertedOK0x0000
Pwr Unit Redundreports redundancy has been lost reports redundancy has been lost, but the unit is still functioning with the minimum amount of resources needed for normal operationWarning0x000A

 

 

-------------------------------------------------------------

 

Is it something in relation to running the updates via OFU and the message stated immediately after starting the update sequece?:

"SDR Auto-Configuration is not supported on this platform"

 

Would rerunning the update package in EFI help the recognition of the psu´s?

 

 

Please if anyone has suggestions on how to work this out chip in.

 

Best Regards Peter

Unable to install Ubuntu 14.04 or higher, Centos 7 or higher on S2600cp server board system

$
0
0

I was trying to install Ubuntu 14.04LTS, 15.04 and CentOS 7, 7.1 on my S2600CP2 server board based system for several days. With Ubuntu 14.04 or higher, install procedure was terminated shortly after the Ubuntu logo showed up, showing the error message: “ i8042 no controller found”. With Centos 7 or higher, after choosing “install Centos 7”, same error showed and the computer restarted.


I learned later this error has something to do with PS/2 mouse or keyboard. In the bios setup, set “Port 60/64 Emulation” to be Disabled, all went well until the installation setup options for both Ubuntu 14.04 and Centos 7, but usb keyboard and mouse are disabled, I can’t choose an option or type in anything. Then have to reboot use the power button.


Please help me with this, there must be a way to solve this problem. Thanks in advance.

Intel Deployment Assistant on USB - unable to access boot device?

$
0
0

Hi I have an old S5000PSL server. Am trying to use Intel Deployment Assistant (most recent version 014). Got the ISO image and transferred to USB as a bootable image using Rufus. When I boot, I get the splash screen saying that the application is loading, then a text screen indicating that it's unable to access the boot device and whether it should restart. A restart of course yields the same result. Any thoughts or suggestions would be most appreciated.

RAID Web Console 2 does not discover local server

raw ipmi command to retrieve NIC 1 MAC address on S2600GZ

$
0
0

Hi there,

 

what is the right approach to retrieve the NIC 1 MAC address (for OS usage) via IPMI?

 

NOTE: I am assuming the system is powered off and that a DHCP server assigned an IP address to the BMC LAN channel 1.

 

The S2600GZ technical product specification section 6.10.3.2.3 highlights the convention used to assign MAC address so conceptually one could calculate it from the BMC LAN channel 1 MAC address (by subtracting 4) but that seems brittle so I am looking for the (raw) IPMI command to provide that info directly!?

 

Other vendors implemented vendor-specific IPMI commands but I can't seem to find the doc that would cover an S2600GZ board..

 

Thanks & cheerio, Harry.

Viewing all 3319 articles